  ver : d_2 update : 2015.09.04 led power alf100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. alf100-12s ALF100-24S alf100-36s alf100-48s alf100-54s max output wattage (w) 100w voltage 90-305 vac or 120-430 vdc frequency (hz) 47-63 hz current (full load) 1.5 a max. (115 vac) / 0.7 a max. (230 vac) / 0.6 a max. (277 vac) inrush current (<2ms) 40 a max. (115 vac) / 60 a max. (230 vac) leakage current <0.75 ma max. input power factor pf>0.97 (115 vac) / pf>0.9 (230 vac) at full load voltage (v.dc.) 12v 24v 36v 48v 54v constant current range (v.dc.) 6~12v 12~24v 18~36v 24~48v 27~54v voltage accuracy 2% current (convection) (ma) max 8333 4166 2777 2083 1852 current adj range (ma) 833 ~ 8333 416 ~ 4166 277 ~2777 208 ~ 2083 185 ~ 1852 voltage adj range (v.dc.) (for ip65 design) 10.8~13.2v 21.6~26.4v 32.4~38.5v 43.2~50.4v 48.6~55.5v line regulation 1% load regulation 1% maximum capacitive load 100,000 uf 50,000 uf 8,000 uf 4,000 uf 3,000 uf ripple & noise (max.) 100mvp-p 100mvp-p 100mvp-p 200mvp-p 200mvp-p efficiency (typ.) 89% 91.5% 91.5% 91.5% 91.5% output hold-up time 25 ms min. safety agency approvals ul 8750 en61347-1:2008 en61347-2-13:2006 emi (conducted & radiated emission) en 55015 class b ems (noise immunity) en 61547 emc surge ip65 design :1kv l-n, 2kv l n-fg / ip67 design :2kv l-n, 4kv l n-fg over power protection auto recovery over voltage protection auto recovery overt temperature protection auto recovery protection short circuit protection auto recovery input-output (v.ac) 3750v input-fg (v.ac) 1880v isolation output-fg . (v.ac) 500v key features ? ip65/67 design for indoor or led outdoor installations ? universal input: 90-305 vac or 120-430 vdc ? bulit-in active pfc function ? free air convection ? high reliability ? with constant current & constant voltage ? output voltage and constant current level can be adjusted through inte rnal potentiometer ? led power application ? 3-year product warranty
ver : d_2 update : 2015.09.04 led power alf100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. alf100-12s ALF100-24S alf100-36s alf100-48s alf100-54s operating temperature -30c?+70c (with derating) storage temperature -40c?+85c temperature coefficient 0.02%/c ( 0~50c ) humidity 95% rh mtbf >127,000 h @ 25c (mil-hdbk-217f) environment vibration 10~500hz, 5g 10min./1cycle, 60min. each along x, y, z axes. dimension (l x w x h) 6.44 x 2.79 x 1.5 inches ( 163.7 x 71.0 x 38.0 mm ) tolerance ? 0.5 mm weight 635 g physical cooling method free air convection note 1. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 2. it's recommended to add varistor 14s561k at l / n input side in parallel. this series has ip65 and ip67, when you place order, please be noted as ordering part no. model no. alf100-12s ALF100-24S alf100-36s alf100-48s alf100-54s ip65 alf100-12s-ip65 ALF100-24S-ip65 alf100-36s-ip65 alf100-48s-ip65 alf100-54s-ip65 ordering part no ip67 alf100-12s-ip67 ALF100-24S-ip67 alf100-36s-ip67 alf100-48s-ip67 alf100-54s-ip67 derating block diagram
ver : d_2 update : 2015.09.04 led power alf100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- mechanical dimension ( top view ) ip65 design ip67 design alf100-12s, 24s, 36s, 48s, 54s assembly instructions *u case t=2.5mm customer screws into the length of the case no higher than 0.5mm ( namel y screw len g th for load p late thickness p lus 3.0mm
ver : d_2 update : 2015.09.04 led power alf100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- dimming operation output constant current level can be adjus ted through output cable by connecting a 3~10vdc or 10v pwm signal between dim+ and dim- i. 3~10v dimming function for out put current adjustment (typ.) 0.0% 10.0% 20.0% 30.0% 40.0% 50.0% 60.0% 70.0% 80.0% 90.0% 100.0% 110.0% 3v 4v 5v 6v 7v 8v 9v 10v dim (v) io (%) ii. 10v pwm signal for output current adjus tment (typ.) : frequency range:100hz~3khz 0.0% 10.0% 20.0% 30.0% 40.0% 50.0% 60.0% 70.0% 80.0% 90.0% 100.0% 110.0% 30% 40% 50% 60% 70% 80% 90% 100% dim(pwm) io (%)
ver : d_2 update : 2015.09.04 led power alf100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -5- efficiency versus load alf100-12s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 86.70 88.61 90.36 90.61 90.36 input voltage (v) 277 305 efficiency (%) 90.36 90.36 load (%) 0 10 20 30 40 50 115v (%) 0 78.83 82.61 86.10 87.62 88.25 230v (%) 0 67.92 78.75 83.11 86.31 88.09 load (%) 60 70 80 90 100 115v (%) 88.58 88.54 88.62 88.57 88.51 230v (%) 89.24 89.71 89.91 90.25 90.61 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v 277v 305v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% ALF100-24S vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.71 90.65 92.27 92.27 92.14 input voltage (v) 277 305 efficiency (%) 92.14 92.40 load (%) 0 10 20 30 40 50 115v (%) 0 71.91 82.20 86.04 87.80 88.81 230v (%) 0 65.13 76.60 82.51 85.92 87.91 load (%) 60 70 80 90 100 115v (%) 89.54 90.26 90.12 90.34 90.43 230v (%) 89.28 90.61 91.47 92.20 92.31 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v 277v 305v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : d_2 update : 2015.09.04 led power alf100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -6- efficiency versus load alf100-36s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 88.82 90.67 92.10 92.01 91.42 input voltage (v) 277 305 efficiency (%) 91.36 91.53 load (%) 0 10 20 30 40 50 115v (%) 0 73.59 82.19 85.65 87.60 89.01 230v (%) 0 65.58 76.12 81.72 85.42 87.77 load (%) 60 70 80 90 100 115v (%) 89.29 90.38 90.80 90.97 90.89 230v (%) 88.78 89.89 91.24 91.68 92.43 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v 277v 305v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff% alf100-48s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 89.15 90.83 92.09 92.01 91.42 input voltage (v) 277 305 efficiency (%) 91.25 91.25 load (%) 0 10 20 30 40 50 115v (%) 0 71.89 81.99 85.76 87.48 88.59 230v (%) 0 61.76 75.28 80.88 84.90 87.04 load (%) 60 70 80 90 100 115v (%) 89.48 90.16 90.40 90.73 90.85 230v (%) 88.77 89.95 90.66 91.27 92.01 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v 277v 305v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%
ver : d_2 update : 2015.09.04 led power alf100 series 100 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -7- efficiency versus load alf100-54s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) 89.11 91.04 92.56 92.82 92.73 input voltage (v) 277 305 efficiency (%) 92.58 92.22 load (%) 0 10 20 30 40 50 115v (%) 0 67.86 77.81 84.01 86.71 88.96 230v (%) 0 58.78 73.10 81.29 84.94 87.15 load (%) 60 70 80 90 100 115v (%) 89.80 90.32 90.75 91.12 91.04 230v (%) 89.06 90.30 91.60 92.93 92.82 70.00% 72.50% 75.00% 77.50% 80.00% 82.50% 85.00% 87.50% 90.00% 92.50% 95.00% 90v 115v 180v 230v 264v 277v 305v vin eff% 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% load eff%


▲Up To Search▲   

 
Price & Availability of ALF100-24S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X